Moisture Measuring Sensors
FSV - The Universal

FSV - The Universal

Adjustable flange probe for universal applications. Wide range of adjustment possible. Also suitable for thick wall situations. Can be mounted on a glider for measuring the moisture of materials on conveyer belts.

Technical data

Protection against Overvoltage, polarity and short-circuit of the output
All inputs and outputs are protected against disturbances with suppression filters.
Depth of insertion of the sensor edge 9 mm Standard (synthetic material protection overlay)
11 mm with Ceramics, Rubber or Teflon overlay
Measurement range & internal calibration 0% and % adjusting trimmer for calibrating the probe (optional)
These allow one to adjust the measuring window of the probe to the desired range of moisture measurements for the material.
Accessible only through a water tight screw on the probe cover.
Environmental conditions Operational: +0.5°C to +50°C (Temperature range G50, Standard)
+0.5°C to +80°C (Temperature range G80, optional)

permissible environmental temperature max 80 °C
Storage: -25°C to +65°C
Probe supply FSV30 = 10 V-30 V DC
FSV = +/-15 V (Tolerance each +/-0,5 V)
Maximum Signal Values Voltage output: -0,7 V to app. 13V (RL = 100 k Ohm)
Current output 0-20 mA: -1,4 mA to app.. 24 mA (Load = 500 Ohm)
Current output 4-20 mA: +4 mA to app. 24mA (Load = 500 Ohm)
Protection level for the probes IP50
Connection to the probe Connecting cable: 5 x 0.22 mm2 shielded
Cable is assembled with metallic terminal sleeves. Plug is optional.
Material-Temperature sensor PT100 (optional)
Abrasion Protection of Sensor Standard: Surface material is synthetic
Ceramic: 3 mm thick, extremely good resistance to abrasion but brittle
Special rubber: extremley abrasion-resistant,impassible for bump/ shocks
Teflon: for sticky materials and for use in the food industry
Conformance: Conforms to CE standard EMV89/336EWG
Protection against damage by lightning Sometimes, especially in open air installations, the probe can be damaged by lightning. In addition to reducing the risk by observing the guide lines laid down in the standard, VDE 185, Parts 1 and 2, it is necessary to equalize the potential between the probe and the processing electronic unit. This is achieved by earthing the cable shielding at both ends.
Signal output Standard: 0-10 V
Output load resistance: 100 kohm

Option: 0-20 mA or 4-20 mA
Load resistance: 500 Ohm 0.1%, TK = 25 ppm
Current input 30 mA (at +15 V for voltage output of 0-10 V)
30 mA (at –15 V for voltage output of 0-10 V)
50 mA (at +15 V for current output 0-20 mA)
30 mA (at –15 V for current output 0-20 mA)

10-30 V Probes: 9V-30V DC
Current input: 190 mA for 10 V Supply
120 mA for 15 V Supply
80 mA for 24 V Supply
70 mA for 30 V Supply

Technical documentations

Equipment Description FSx - Sensors (german)

Equipment Description FSx - Sensors (german)

germanenglishfrenchrussian


Sensors in use

FSV on a glider - dried sludge measurementFSV on a glider - sand moisture on a conveyer beltFSV on a glider - sand moisture on a conveyer beltFSV on a glider - sand moisture on a conveyer belt
FSV on a glider - wood chips on a conveyer belt

ContactAbout us
© 2001-2008 Werne & Thiel GmbH
 
stop autoplay vorheriges Bild nächstes Bild Galerie schließen